<?xml version="1.0" encoding="utf-8"?>
<feed xmlns="http://www.w3.org/2005/Atom">
  <title>Certorum guides for field certifiers</title>
  <link href="https://certorum.com/guides"/>
  <link rel="self" href="https://certorum.com/guides/feed.xml"/>
  <id>https://certorum.com/guides</id>
  <updated>2026-10-22T00:00:00Z</updated>
  <author><name>Certorum</name></author>
  <entry>
    <title>Handbook 44 scale test procedures</title>
    <link href="https://certorum.com/guides/handbook-44-scale-test-procedures"/>
    <id>https://certorum.com/guides/handbook-44-scale-test-procedures</id>
    <updated>2026-10-22T00:00:00Z</updated>
    <summary>The field tests NIST Handbook 44 Section 2.20 prescribes for commercial scales — increasing-load, decreasing-load, shift, repeatability, discrimination and zero-load balance — with the test loads and how each result is judged.</summary>
  </entry>
  <entry>
    <title>NIST Handbook 44 scale tolerances explained</title>
    <link href="https://certorum.com/guides/handbook-44-scale-tolerances"/>
    <id>https://certorum.com/guides/handbook-44-scale-tolerances</id>
    <updated>2026-10-22T00:00:00Z</updated>
    <summary>How NIST Handbook 44 sets tolerances for commercial scales: verification scale intervals (e), accuracy classes I to IIII and III L, the Table 6 tolerance steps, when acceptance or maintenance tolerances apply, and worked examples.</summary>
  </entry>
  <entry>
    <title>Placed-in-service reports for scales</title>
    <link href="https://certorum.com/guides/scale-placed-in-service-reports"/>
    <id>https://certorum.com/guides/scale-placed-in-service-reports</id>
    <updated>2026-10-22T00:00:00Z</updated>
    <summary>What a placed-in-service report is, when a registered scale serviceperson or agency must file one, the 24-hour model rule in NIST Handbook 130, what the report records, and how states differ.</summary>
  </entry>
  <entry>
    <title>Test weights for scale service</title>
    <link href="https://certorum.com/guides/scale-test-weight-calibration"/>
    <id>https://certorum.com/guides/scale-test-weight-calibration</id>
    <updated>2026-10-22T00:00:00Z</updated>
    <summary>What registered scale service agencies need to know about field standard test weights — NIST 105-series specifications, calibration by the state or an accredited lab, intervals, the one-third rule from Handbook 44, and the records to keep.</summary>
  </entry>
  <entry>
    <title>USP &lt;797&gt; cleanroom certification: what's tested every six months</title>
    <link href="https://certorum.com/guides/usp-797-cleanroom-certification"/>
    <id>https://certorum.com/guides/usp-797-cleanroom-certification</id>
    <updated>2026-10-22T00:00:00Z</updated>
    <summary>What a USP &lt;797&gt; (2023) certification covers for pharmacy cleanrooms and PECs — particle counts under dynamic conditions, HEPA leak tests, air changes, pressure differentials and smoke studies — plus the USP &lt;800&gt; hazardous-drug room requirements.</summary>
  </entry>
  <entry>
    <title>ASHRAE 110 fume hood testing: procedure, ratings and acceptance criteria</title>
    <link href="https://certorum.com/guides/ashrae-110-fume-hood-testing"/>
    <id>https://certorum.com/guides/ashrae-110-fume-hood-testing</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>How an ASHRAE 110 fume hood test works — face velocity, smoke visualization, tracer gas containment and sash movement — what AM, AI and AU ratings mean, and the acceptance criteria most labs use.</summary>
  </entry>
  <entry>
    <title>Biosafety cabinet classes and types explained</title>
    <link href="https://certorum.com/guides/biosafety-cabinet-types"/>
    <id>https://certorum.com/guides/biosafety-cabinet-types</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>The differences between Class I, II and III biosafety cabinets and the Class II types A1, A2, B1, B2 and C1 — inflow velocity, how much air is recirculated or exhausted, how each is connected to the building, and what that means when you certify one.</summary>
  </entry>
  <entry>
    <title>What a biosafety cabinet certification report should include</title>
    <link href="https://certorum.com/guides/bsc-certification-report"/>
    <id>https://certorum.com/guides/bsc-certification-report</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>A field-tested checklist for biosafety cabinet certification reports — cabinet identification, standard, certifier and NSF accreditation, instruments and calibration, every NSF/ANSI 49 reading against its criterion, as-found and as-left data, and the label.</summary>
  </entry>
  <entry>
    <title>How often do biosafety cabinets, fume hoods and cleanrooms need certification?</title>
    <link href="https://certorum.com/guides/certification-frequency"/>
    <id>https://certorum.com/guides/certification-frequency</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>Certification intervals for biosafety cabinets, compounding PECs, pharmacy cleanrooms, ISO cleanrooms and chemical fume hoods — the minimum interval, what resets the clock, and which standard sets it.</summary>
  </entry>
  <entry>
    <title>Cleanroom air changes per hour: how to calculate and verify them</title>
    <link href="https://certorum.com/guides/cleanroom-air-changes-per-hour"/>
    <id>https://certorum.com/guides/cleanroom-air-changes-per-hour</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>How to calculate cleanroom air changes per hour from measured HEPA diffuser airflow and room volume, with a worked example, the USP &lt;797&gt; and &lt;800&gt; minimums, and the mistakes that make ACPH numbers wrong.</summary>
  </entry>
  <entry>
    <title>ISO 14644-1:2015 cleanroom classification: class limits, sample locations and sample volume</title>
    <link href="https://certorum.com/guides/iso-14644-1-cleanroom-classification"/>
    <id>https://certorum.com/guides/iso-14644-1-cleanroom-classification</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>How to classify a cleanroom to ISO 14644-1:2015 — the class limit formula and table, how many sample locations a room needs, the minimum sample volume, the acceptance rule, and how often to reclassify under ISO 14644-2.</summary>
  </entry>
  <entry>
    <title>Biosafety cabinet certification: NSF/ANSI 49 field tests and acceptance criteria</title>
    <link href="https://certorum.com/guides/nsf-49-biosafety-cabinet-certification"/>
    <id>https://certorum.com/guides/nsf-49-biosafety-cabinet-certification</id>
    <updated>2026-10-20T00:00:00Z</updated>
    <summary>The NSF/ANSI 49 field tests for Class II biosafety cabinets — downflow, inflow, smoke patterns, HEPA filter leak and site installation — with the usual acceptance criteria, when to certify and why cabinets fail.</summary>
  </entry>
</feed>
