Guides for field certifiers

The standards behind every test visit

What NSF/ANSI 49, ASHRAE 110, USP <797>, ISO 14644 and NIST Handbook 44 ask for in the field: the tests, the acceptance criteria, how often, and what the report needs to show.

Biosafety cabinets, fume hoods and cleanrooms

NSF/ANSI 49, ASHRAE 110, USP <797> and ISO 14644 in the field.

ASHRAE 110 fume hood testing: procedure, ratings and acceptance criteriaHow an ASHRAE 110 fume hood test works — face velocity, smoke visualization, tracer gas containment and sash movement — what AM, AI and AU ratings mean, and the acceptance criteria most labs use.Read the guide · 4 min →Biosafety cabinet classes and types explainedThe differences between Class I, II and III biosafety cabinets and the Class II types A1, A2, B1, B2 and C1 — inflow velocity, how much air is recirculated or exhausted, how each is connected to the building, and what that means when you certify one.Read the guide · 3 min →What a biosafety cabinet certification report should includeA field-tested checklist for biosafety cabinet certification reports — cabinet identification, standard, certifier and NSF accreditation, instruments and calibration, every NSF/ANSI 49 reading against its criterion, as-found and as-left data, and the label.Read the guide · 3 min →How often do biosafety cabinets, fume hoods and cleanrooms need certification?Certification intervals for biosafety cabinets, compounding PECs, pharmacy cleanrooms, ISO cleanrooms and chemical fume hoods — the minimum interval, what resets the clock, and which standard sets it.Read the guide · 2 min →Cleanroom air changes per hour: how to calculate and verify themHow to calculate cleanroom air changes per hour from measured HEPA diffuser airflow and room volume, with a worked example, the USP <797> and <800> minimums, and the mistakes that make ACPH numbers wrong.Read the guide · 3 min →ISO 14644-1:2015 cleanroom classification: class limits, sample locations and sample volumeHow to classify a cleanroom to ISO 14644-1:2015 — the class limit formula and table, how many sample locations a room needs, the minimum sample volume, the acceptance rule, and how often to reclassify under ISO 14644-2.Read the guide · 3 min →Biosafety cabinet certification: NSF/ANSI 49 field tests and acceptance criteriaThe NSF/ANSI 49 field tests for Class II biosafety cabinets — downflow, inflow, smoke patterns, HEPA filter leak and site installation — with the usual acceptance criteria, when to certify and why cabinets fail.Read the guide · 6 min →USP <797> cleanroom certification: what's tested every six monthsWhat a USP <797> (2023) certification covers for pharmacy cleanrooms and PECs — particle counts under dynamic conditions, HEPA leak tests, air changes, pressure differentials and smoke studies — plus the USP <800> hazardous-drug room requirements.Read the guide · 4 min →

Scale service

NIST Handbook 44 tolerances and tests, placed-in-service reports and test weights.

Certify to these standards without the binder

Certorum checks each reading against the right standard as you type it on site, issues the certificate and invoice when you sign off, and keeps every unit on its recertification cycle. Free for up to 40 units.