NIST Handbook 44 scale tolerances explained
Updated · 5 min read
On this page
Every commercial scale in the US is judged against NIST Handbook 44, Specifications, Tolerances, and Other Technical Requirements for Weighing and Measuring Devices, which the states adopt as their scale code. Section 2.20 covers scales. This guide explains how its tolerances work, using the 2026 edition: what "e" is, how the accuracy class sets the tolerance steps, and which tolerance applies on a given visit.
Your state may adopt a particular edition, or amend it; check which one applies before relying on the numbers here.
Tolerances are counted in e
Handbook 44 expresses scale tolerances in verification scale intervals (e), the interval used to classify and test the scale, which is marked on the device. On most commercial scales e is the same as the displayed division (d), but not always, so read it from the data plate rather than the display.
To find a tolerance:
- Express the test load in e: test load ÷ e. A 30 lb test load on a scale with e = 0.01 lb is 3,000 e.
- Look up that number of e in Table 6 for the scale's accuracy class. That gives the maintenance tolerance in e.
- Convert back: tolerance in e × e.
Accuracy classes
The class is marked on the scale and depends on the size of e and the number of intervals (n = capacity ÷ e). Handbook 44 Table 3 sets the ranges:
| Class | Typical use | e | n |
|---|---|---|---|
| I | Precision laboratory | 1 mg or more | 50,000 or more |
| II | Laboratory, precious metals, gems | 1 mg to 50 mg, or 100 mg and up | 100 to 100,000 (5,000 to 100,000 when e is 100 mg or more) |
| III | Most commercial scales: retail, shipping, livestock | 0.1 g to 2 g (0.0002 lb to 0.005 lb), or 5 g (0.01 lb) and up | 100 to 10,000 (500 to 10,000 for the larger e) |
| III L | Vehicle, axle-load, railway track, crane and hopper scales | 2 kg (5 lb) or more | 2,000 to 10,000 |
| IIII | Wheel-load weighers and other coarse weighing | 5 g (0.01 lb) or more | 100 to 1,200 |
If the capacity divided by e comes out above the class maximum, recheck the marking before testing.
Table 6: the tolerance steps
These are the maintenance tolerances (Handbook 44 Table 6, 2026). The test load is in e; the tolerance is ± that many e.
| Class | ±1 e | ±2 e | ±3 e | ±5 e |
|---|---|---|---|---|
| I | 0 to 50,000 e | 50,001 to 200,000 e | 200,001 e and up | — |
| II | 0 to 5,000 e | 5,001 to 20,000 e | 20,001 e and up | — |
| III | 0 to 500 e | 501 to 2,000 e | 2,001 to 4,000 e | 4,001 e and up |
| IIII | 0 to 50 e | 51 to 200 e | 201 to 400 e | 401 e and up |
| III L | 0 to 500 e | 501 to 1,000 e | add 1 e for each additional 500 e, or fraction of 500 e |
Maintenance or acceptance?
Acceptance tolerances are one-half the maintenance tolerances (T.N.3.2). Which one applies depends on the device's history, under General Code G-T.1 and G-T.2.
Acceptance tolerances apply to equipment:
- being put into commercial use for the first time;
- placed in commercial service within the last 30 days and being officially tested for the first time;
- returned to service after official rejection, and officially tested for the first time within 30 days of the corrective service;
- officially tested for the first time within 30 days of major reconditioning or overhaul;
- undergoing type evaluation.
Maintenance tolerances apply to everything else in actual use.
In practice, a service technician placing a scale in service or returning it after repair should leave it well inside acceptance tolerance. The registered-servicer regulation in NIST Handbook 130 also asks for devices to be adjusted "as closely as practicable to zero error".
Worked examples
A 60 lb retail scale, Class III, e = 0.01 lb (n = 6,000):
| Test load | In e | Maintenance | Acceptance |
|---|---|---|---|
| 5 lb | 500 e | ±0.01 lb | ±0.005 lb |
| 10 lb | 1,000 e | ±0.02 lb | ±0.01 lb |
| 30 lb | 3,000 e | ±0.03 lb | ±0.015 lb |
| 60 lb | 6,000 e | ±0.05 lb | ±0.025 lb |
A 100,000 lb vehicle scale, Class III L, e = 20 lb (n = 5,000):
| Test load | In e | Maintenance | Acceptance |
|---|---|---|---|
| 10,000 lb | 500 e | ±20 lb | ±10 lb |
| 20,000 lb | 1,000 e | ±40 lb | ±20 lb |
| 40,000 lb | 2,000 e | ±80 lb | ±40 lb |
| 100,000 lb | 5,000 e | ±200 lb | ±100 lb |
The scale tolerance calculator does this for any class, e and test load, and checks your readings against both tolerances.
Special cases
- Class IIII wheel-load weighers and portable axle-load weighers: twice the normal tolerances (T.N.3.3).
- Crane and hopper scales (other than grain hopper): Class III L tolerances, but for crane and construction-materials hopper scales the tolerance is never less than 1 e or 0.1 % of capacity, whichever is less (T.N.3.4).
- Ratio tests: 0.75 of the applicable tolerance (T.N.2.5).
- Multi-interval and multiple-range scales: use the e of the range in use (T.N.2.4).
- Tare: tolerances apply to the net indication from the tare zero (T.N.2.1).
The tests themselves, and how their results are judged, are in Handbook 44 scale test procedures.
Certorum for scale service agencies
Handbook 44 tolerances checked as you enter each test load, as-found and as-left results on one report, placed-in-service reports, test weights on record and the invoice from the same visit. Free for up to 40 scales.
More guides
- Handbook 44 scale test procedures
- Placed-in-service reports for scales
- Test weights for scale service
- ASHRAE 110 fume hood testing: procedure, ratings and acceptance criteria
- Biosafety cabinet classes and types explained
- What a biosafety cabinet certification report should include
- How often do biosafety cabinets, fume hoods and cleanrooms need certification?
- Cleanroom air changes per hour: how to calculate and verify them
- ISO 14644-1:2015 cleanroom classification: class limits, sample locations and sample volume
- Biosafety cabinet certification: NSF/ANSI 49 field tests and acceptance criteria
- USP <797> cleanroom certification: what's tested every six months